Cougar USA Blog

Tip of the Week - Exterior Features Elite Sump Pump Control Panel

May 22, 2019 12:14:00 PM / by Cougar USA Marketing posted in Tip of the Week

0 Comments

In this week's video we will show you the exterior features of the Cougar Systems Elite Sump Pump Control Panel.

Read More

Tip of the Week - Touchscreen Features Elite Level Control Panel

May 16, 2019 12:11:00 PM / by Cougar USA Marketing posted in Tip of the Week

0 Comments

In this week's tip we will show you the Touchscreen features of the Cougar Systems Elite Level Control Panel.

Read More

Tip of the Week - Change Level Sensor Settings Elite Level Control Panel

May 8, 2019 12:08:00 PM / by Cougar USA Marketing posted in Tip of the Week

0 Comments

In this week's video we will show you how to change the Level Sensor Settings on the Cougar Systems Elite Level Control Panel.

Read More

Tip of the Week - Change Fill Valve Settings Elite Level Control Panel

May 1, 2019 12:04:00 PM / by Cougar USA Marketing posted in Tip of the Week

0 Comments

This week's tip shows you how to change the Fill Valve Settings on the Cougar Systems Elite Level Control Panel.

Read More

Tip of the Week - External Features Elite Level Control Panel

Apr 24, 2019 12:00:00 PM / by Cougar USA Marketing posted in Tip of the Week

0 Comments

On this week’s tip of the week video we will show you the external features of the Cougar Systems Elite Level Control Panel.

Read More

Avoiding Cavitation in Water Pressure Reducing Valves

Apr 23, 2019 11:15:00 AM / by Tim Zacharias posted in Pressure

0 Comments

High-rise buildings present multiple challenges for water distribution due to the high pressures required to reach the top of the building. The high pressures in the lower levels of the building cause high-pressure drops across Pressure Reducing Valves (PRVs), over 100 PSI or more, creating the potential for cavitation within the valves.

Read More

Design Considerations for Water Pressure Reducing Valve (PRV) Stations in Commercial Buildings

Apr 15, 2019 10:49:32 AM / by Tim Zacharias posted in Pressure

1 Comment

Pressure Reducing Valve (PRV) Stations are an important component of a water-distribution system in a commercial building. The 2015 Uniform Plumbing Code Section 608.2 states that PRVs are required at any point where the system static pressure exceeds 80 PSI. Typically, this applies to mid- and high-rise buildings when the pressure boost required at the ground floor to serve the upper floors in the building is over 80 PSI. When designing a PRV Station, you must consider the station pressure drop, water flow, and safety devices.

Read More

Tip of the Week - Elite Level Sequence Settings

Apr 10, 2019 10:32:00 AM / by Cougar USA Marketing posted in Tip of the Week

0 Comments

This week’s tip will show you the Sequence of Operation of the Cougar Systems Elite Level Control Panel.

Read More

Tip of the Week - Grundfos Magna3 Flow Limit

Apr 3, 2019 10:28:00 AM / by Cougar USA Marketing posted in Tip of the Week

0 Comments

This week’s tip shows how to enable and set the Flow Limit feature on the Grundfos Magna3 Pump which eliminates the need for a flow control valve.

Read More

Tip of the Week - Grundfos Magna3 Units of Measure

Mar 27, 2019 10:26:00 AM / by Cougar USA Marketing posted in Tip of the Week

0 Comments

This week’s tip shows how to change the Units of Measure on the Grundfos Magna3 Pump.

Read More